I came upon this not long ago and found the following when doing a "show stack".
Core#sh stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6610-48P active 748e.f892.1234 0 local Ready
2 S ICX6610-24P member 748e.f8e7.4567 0 remote NON-OP: image mismatch
active
+---+ +---+
=2/1| 1 |2/6==2/1| 2 |2/6=
| +---+ +---+ |
| |
|------------------------|
Note: There is no standby. Reason: u2: not operational,
Current stack management MAC is 748e.f892.1234
Core#
Current stack management MAC is 748e.f892.1234
Core#Warning! put unit 2 MAC=748e.f8e7.4567 to non-operational, reason= config mismatch
Unit 1 loses all neighbors.
Active unit 1 deletes u2 but keeps its static config.
So the solution in this case was to make sure the images on both the ICXs were the same. They were not, as you can see from the first highlighted portion of the message. It shows the topology of the stack, but its non-operational. Upgrading the image resolved the problem here.